Fenomeno De Reentrada Pdf Printer

Fenomeno de reentrada pdf printer

Los 3 mecanismos principales de las arritmias cardiacas son las alteraciones en el automatismo, la actividad desencadenada y la reentrada. Cardiac arrhythmias are prevalent among humans across all age ranges and may occur in the setting of underlying heart disease as well as in structurally normal hearts. While arrhythmias are widely varied in their clinical presentations, they possess shared electrophysiologic properties at the cellular level.

The 3 main mechanisms responsible for cardiac arrhythmias are automaticity, triggered activity, and reentry.

Fenomeno de reentrada pdf printer

Although identifying the specific mechanism may at times be challenging for the clinician and require invasive electrophysiologic study, differentiating and understanding the underlying mechanism may be critical to the development of an appropriate diagnosis and treatment strategy..

Full English text available from: www. Figura 1. Al alcanzar el potencial de membrana en reposo, el ciclo se repite continuamente una y otra vez..

Fenomeno de reentrada pdf printer

Figura 2. Figura 3. Mecanismos de aumento de automatismo normal. A: normal. B: aumento del umbral de voltaje. Figura 4. Figura 5. Se postula que el automatismo anormal puede aparecer en los casos de potasio extracelular elevado, pH intracelular bajo y exceso de catecolaminas..

Figura 6. A: pospotencial precoz en fase 2. B: pospotencial precoz en fase 3.

Taquicardia por Reentrada de la Unión AV o Intranodal

La fase de meseta del PA es un periodo de alta resistencia de membrana 3 y bajo flujo de corriente. Tabla 2. Agentes y manipulaciones que pueden conducir a pospotenciales precoces. Las arritmias inducidas por PPP dependen de la frecuencia y, en general, la amplitud de los PPP aumenta a frecuencias lentas.

Cuando todas las fibras se han despolarizado y se encuentran en una fase completamente refractaria, el impulso se extingue.

Menú de navegación

Figura 7. El intervalo o gap excitable es un concepto clave esencial para comprender el mecanismo de reentrada Figura 8. Se denomina intervalo o gap excitable al miocardio excitable que existe entre el frente de la onda de reentrada y la cola de la onda precedente Figura 8. Como se ha indicado previamente, los circuitos de reentrada funcionales pueden deberse a diferentes mecanismos:. Figura 9. Figura Las ondas espirales se pueden producir en una amplia variedad de entornos en los que existe tejido excitable Encarrilamiento entrainment.

El encarrilamiento es el reciclaje continuo de un circuito de taquicardia Figura A: circuito de reentrada. Puede observarse en el ECG de superficie si se despolariza una cantidad significativa de miocardio 34 o en registros intracardiacos. Esto requiere que el circuito reentrante posea zonas de entrada y salida bien diferenciadas.

Cuadro clínico de la taquicardia intranodal

Tabla 4. Maniobras para diferenciar los distintos mecanismos de las arritmias. Estas arritmias se suelen interrumpir en respuesta a la adenosina.. El ECG de superficie puede no confirmar un determinado mecanismo, pero nos aporta pistas importantes Las bradiarritmias pueden explicarse por dos mecanismos Figura 14 :.

Esta forma de bradiarritmia se observa con frecuencia en el contexto de procesos degenerativos. Las taquicardias auriculares pueden deberse a automatismo, AD o mecanismos de reentrada, pero la mayor parte de ellas corresponden a alteraciones del automatismo o a mecanismos de reentrada. AV: auriculoventricular; CAP: complejo auricular prematuro.. Pueden estar relacionadas con aumento del automatismo normal, automatismo anormal o AD La FA preexcitada puede derivar en FA y parada cardiaca.

El proceso postinfarto da lugar a una cicatriz asociada a islotes de miocitos supervivientes. Aunque la patogenia no se conoce por completo, su comportamiento indica que muchas de ellas se deben a AD como resultado de pospotenciales.. Read this article in English. Mechanisms of Cardiac Arrhythmias. Descargar PDF. Palabras clave:.

Taquicardia de reentrada del nódulo AV

Although identifying the specific mechanism may at times be challenging for the clinician and require invasive electrophysiologic study, differentiating and understanding the underlying mechanism may be critical to the development of an appropriate diagnosis and treatment strategy. Texto completo. Arrhythmogenic mechanisms: automaticity, triggered activity and reentry..

Arrhythmogenic mechanisms: automaticity, triggered activity and reentry. Mechanisms of cardiac arrhythmias. Molecular and cellular basis of cardiac electrophysiology.. Molecular and cellular basis of cardiac electrophysiology.

J Cardiovasc Electrophysiol.

Genesis and regulation of the heart automaticity.. Physiol Rev. Electrophysiological mechanisms of cardiac arrhythmias: clinical arrhythmology and electrophysiology, a companion to Brawnwald's heart disease..

Electrophysiological mechanisms of cardiac arrhythmias: clinical arrhythmology and electrophysiology, a companion to Brawnwald's heart disease.

Taquicardia AV reentrada

Basic cardiac electrophysiology for the clinician.. Basic cardiac electrophysiology for the clinician. Funny channels in the control of cardiac rhythm and mode of action of selective blockers..

Pharmacol Res. Mecanismos de las arritmias cardiacas. Studies on overdrive stimulation of canine cardiac Purkinje fibers: Maximal diastolic potential as a determinant of the response..

J Am Coll Cardiol. Contribution of variable entrance and exit block in protected foci to arrhythmogenesis in isolated ventricular tissues.. Crit Rev Clin Lab Sci.

Fenomeno de reentrada pdf printer

Mechanisms of digitalis toxicity. Effects of ouabain on phase four of canine Purkinje fiber transmembrane potentials.. Electrocardiographic response of digoxin-toxic fascicular tachycardia to Fab fragments: implications for tachycardia mechanism.. Pacing Clin Electrophysiol.

Fenomeno de reentrada pdf printer

Inward sodium current at resting potentials in single cardiac myocytes induced by the ischemic metabolite lysophosphatidylcholine.. Circ Res. Eur Heart J. Adenosine sensitive ventricular tachycardia: evidence suggesting cyclic AMP-mediated triggered activity..

Clasificación electrofisiológica

J Membrane Biology. Genesis of phase 3 early afterdepolarizations and triggered activity in acquired long-QT syndrome..

Fenomeno de reentrada pdf printer

Circ Arrhythm Electrophysiol. Pharmacol Rev. Role of gap junctions in the propagation of the cardiac action potential.. Cardiovasc Res. Basis mechanisms of cardiac impulse propagation and associated arrhythmias.. Cellular electrophysiologic mechanisms of arrhythmias..

Kenwood walkie talkee manual dexterity

Cardiol Clin. Circus movement in rabbit atrial muscle as a mechanism of tachycardia. A new model of circus movement in cardiac tissue without the involvement of an anatomical obstacle..

Cir Res. Influence of anisotropic conduction properties in the propagation of the cardiac action potential.. Prog Biophys Mol Biol.

Mr coffee fttx95-1 owners manual

Initiating reentry: the role of nonuniform anisotropy in small circuits.. Basis mechanisms of reentrant arrhythmias.. Curr Opin Cardiol.